BJAAM Services, Inc.BJAAM Services, Inc.  
ELECTRIC MOTOR REBUILDER WASHWATER
 

Electric Motor Rebuilder Washwater

B-Clear™ is being used to treat washwater from an electric motor rebuilder. Wastewater is generated from a spray booth, and by a steam cleaning operation done on each electric motor prior to rebuilding. The washwater contains high levels of oil and grease, copper, lead and zinc. The wastewater is being treated with 0.06 pounds per gallon of B-Clear™.

The following test results are from the electric motor rebuilder.

ELECTRIC MOTOR REBUILDER WASHWATER TREATMENT RESULTS
TEST UNTREATED
WASTEWATER (PPM)
TREATED
WASTEWATER (PPM)
Oil and Grease 930 12.2
Arsenic NA < 0.050
Barium NA 0.007
Cadmium 0.66 < 0.005
Chromium 0.77 0.044
Copper 28.40 0.023
Lead 3.92 0.010
Mercury < 0.02 < 0.0002
Nickel 1.45 0.617
Selenium NA < 0.05
Silver NA < 0.005
Zinc 33.70 0.369